ALUM-A-LUB CORPORATION -- ALUM-A-LUB SOLVENT BLEND -- -
===================== Product Identification =====================
Product ID:ALUM-A-LUB SOLVENT BLEND
MSDS Date:01/08/1986
FSC:NIIN:Submitter:N EN
Status Code:A
=== Responsible Party ===
Company Name:ALUM-A-LUB CORPORATION
Address:8600 DELMAR BLVD., LOBBY 9
City:ST. LOUIS
State:MO
ZIP:63124
Country:US
Info Phone Num:314-997-6060
Emergency Phone Num:314-997-6060
CAGE:UO426
=== Contractor Identification ===
Company Name:ALUM-A-LUB CORPORATION
Address:8600 DELMAR BLVD., LOBBY 9
Box:City:ST. LOUIS
State:MO
ZIP:63124
Country:US
Phone:314-997-6060
CAGE:UO426
============= Composition/Information on Ingredients =============
Ingred Name:SOLVENTS
= Wt:71.4
ACGIH TLV:25 PPM
Ingred Name:ADDITIVES: PETROLEUM LUBE OIL (CONTAINS SILICONE)
= Wt:28.6
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF OVEREXPOSURE TO VAPORS
MIGHT DAMAGE CENTRAL NERVOUS SYSTEM AND CAUSE RESPIRATORY
IRRITATION, MUSCULAR WEAKNESS, CONFUSION, IMPAIRED COORDINATION,
HEADACHE AND NAUSEA.
Effects of Overexposure:SEE HEALTH HAZARDS ACUTE AND CHRONIC .
======================= First Aid Measures =======================
First Aid:SKIN: WASH IMMEDIATELY WITH SOAP AND WATER. EYES: WASH
IMMEDIATELY WITH PLENTY OF WATER FOR 15 MINUTES. INHALATION: REMOVE
FROM EXPOSURE. PROVIDE FRESH AIR AND REST. USE ARTIFICIAL
RESPIRATION IF NEED ED. INGESTION: DO NOT INDUCE VOMITING. CALL A
PHYSICIAN IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:=55.6C, 132.F
Extinguishing Media:MECHANICAL FOAM, DRY CHEMICAL, WATER FOG, CO*2.
Fire Fighting Procedures:A STRAIGHT WATER STREAM WOULD SPREAD
HYDROCARBON FIRES. AVOID BREATHING VAPORS. USE FRESH AIR
RESPIRATORS (NIOSH APPROVED - ).
Unusual Fire/Explosion Hazard:A VAPOR ACCUMULATION WOULD FLASH AND/OR
EXPLODE IF IGNITED.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL POSSIBLE IGNITION SOURCES. AVOID
BREATHING VAPORS. PROVIDE ADEQUATE VENTILATION. IN CASE OF
SPILLAGE, ABSORB AND DISPOSE OF IN ACCORDANCE WITH LOCAL APPLICABLE
REGULATIONS. CALL EMERGENCY N UMBER IF SPILLAGE POSES THREAT TO MAN
OR ENVIRONMENT.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CLOSURES TIGHT AND UPRIGHT TO
PREVENT LEAKAGE. KEEP CLOSED WHEN NOT IN USE. DO NOT TRANSFER TO
UNMARKED CONTAINER. REAL ALL WARNING LABELS.
Other Precautions:STORE IN COOL, WELL VENTILATED AREA. GROUND
CONTAINERS WHEN FILLING OR EMPTYING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF TLV IS EXCEEDED, USE SELF-CONTAINED BREATHING
APPARATUS (NIOSH APPROVED - ). THRESHOLD LIMIT VALUE: 25 PPM.
Ventilation:LOCAL EXHAUST: TO A DANGER SAFE AREA. MECHANICAL
(GENERAL): USE EXPLOSION-PROOF EQUIPMENT. SPECIAL: ONLY WITH
ADEQUATE (SUPPLEMENTAL SAFETY AND HEALTH)
Protective Gloves:USE CHEMICAL-RESISTANT GLOVES.
Eye Protection:USE SAFETY GOGGLES (ANSI APPROVED - ).
Other Protective Equipment:AS REQUIRED TO AVOID SKIN CONTACT OR
BREATHING VAPORS. EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA .
Supplemental Safety and Health
CHEMICAL NAME AND SYNONYMS: N/A. CHEMICAL FAMILY: ESTER & ALIPHATIC
HYDROCARBONS. FORMULA: N/A. VENTILATION (CONT):
VENTILATION. OTHER: AVOID POTENTIAL IGNITION SOURCES.
================== Physical/Chemical Properties ==================
Boiling Pt:=137.8C, 280.F
Solubility in Water:NEGLIGIBLE
Appearance and Odor:STRAW-COLORED LIQUID WITH CHARACTERISTIC ODOR.
Percent Volatiles by Volume:75.00%
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, FLAME AND OTHER SOURCES OF
IGNITION.
Hazardous Decomposition Products:CARBON MONOXIDE IF BURNED WITH
INSUFFICIENT AIR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS, USE QUALIFIED DISPOSAL COMPANY TO INCINERATE,
OR OTHERWISE DISCARD, AT AN APPROVED FACILITY. DO NOT INCINERATE
CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.